CLASSIFICATIONS: E81T1-B2LC per AWS A5.29, ASME SFA 5.29
Select 810-B2L is a premium low alloy steel electrode intended for
single and multiple pass, all position welding of certain 1 1/4
percent chromium and 1/2 percent molybdenum steel plate and
pipe, where lower carbon levels are required in the weld deposit.
APPLICATIONS: Select 810-B2L is specially designed to weld
thin-walled A335-P11 pipe or tube and is well suited for use in
the fabrication of pressure vessels, heat exchangers and boilers.
DIAMETERS: .045", .052", 1/16"
SHIELDING GAS: 100% CO2, 35-50 cfh
WELDING POSITIONS: All positions
CHARACTERISTICS:
- Smooth arc transfer.
- Low spatter emission.
- Fast freezing slag removes easily.
- Provides improved ductility and lower hardness over conventional, higher carbon grades.
|
TYPICAL
MECHANICAL PROPERTIES
|
| |
SR 1 Hr. at 1275° F
|
| Ultimate Tensile Strength
(psi) |
92,200 |
| Yield Strength (psi) |
79,400 |
| Percent Elongation |
22 |
|
|
TYPICAL
DEPOSIT COMPOSITION
|
| Wt% |
C |
Mn |
P |
S |
Si |
Cr |
Mo |
|
|
.03 |
.80 |
.010 |
.010 |
.30 |
1.10 |
.50 |
|
RECOMMENDED WELDING
PARAMETERS |
|
| Diam. |
Position |
Amps |
Volts |
WFS |
Amps |
Volts |
| 1/16" |
Flat |
350 |
29 |
350 |
150-400 |
22-34 |
| |
Overhead |
225 |
26 |
170 |
150-310 |
22-28 |
| |
Vertical
up |
225 |
25 |
170 |
150-280 |
22-27 |
| .052" |
Flat |
300 |
28 |
440 |
100-330 |
19-32 |
| |
Overhead |
200 |
26 |
245 |
150-310 |
21-28 |
| |
Vertical
up |
200 |
25 |
245 |
150-280 |
21-27 |
| .045" |
Flat |
250 |
28 |
450 |
100-300 |
21-32 |
| |
Overhead |
200 |
26 |
300 |
150-280 |
21-29 |
| |
Vertical
up |
200 |
25 |
300 |
100-230 |
21-28 |
|
Notice: The results reported are based upon testing of the product under controlled laboratory conditions in accordance with American Welding Society Standards. Actual use of the product may produce different results due to varying conditions. An example of such conditions would be electrode size, plate chemistry, environment, weldment design, fabrication methods, welding procedure and service requirements. Thus the results are not guarantees for use in the field. The manufacturer disclaims any warranty of merchantability or fitness for any particular purpose with respect to its products.
|