Select 717 Close Window
 Print Sheet


CLASSIFICATIONS: E71T-1M, T-9M per AWS A5.20, ASME SFA 5.20

Select 717 is a flux cored electrode specially formulated to weld with high argon gas mixtures. Intended for single and multiple pass welding of carbon steels in all positions. The recommended shielding gas is argon with 5-25% carbon dioxide.

APPLICATIONS: Select 717 is best suited for situations where lower fume levels are required or higher out of position productivity is desired. Select 717 may be used to join steels such as ASTM A36, A515 Gr 70, A516 Gr70 and other fine grained steels. Typical applications include railcars, heavy equipment, structural fabrication and general plate fabrication.

DIAMETERS: .045", .052", 1/16"

SHIELDING GAS: 75-95% Ar/balance CO2, 35-50 cfh

WELDING POSITIONS: All positions

CHARACTERISTICS:

  • Very smooth arc transfer with virtually no spatter.
  • Exceptionally low fume generation.
  • Maintains handling characteristics in higher argon mixtures.
  • Quick freezing slag allows for very high deposition rates.

    TYPICAL MECHANICAL PROPERTIES
     
    75% Ar/ 25% CO2
    95% Ar/ 5% CO2
    Ultimate Tensile Strength (psi) 82,400 88,100
    Yield Strength (psi) 69,700 76,000
    Percent Elongation 27 26
    CVN (ft-lb f) @ 0° F 76 97
                      @ -20° F 55 89

    TYPICAL DEPOSIT COMPOSITION
    Wt% C Mn P S Si
    75 Ar/25 CO2
    .04 .96 .007 .010 .49
    95 Ar/5 CO2
    .04 1.12 .007 .010 .59

    RECOMMENDED WELDING PARAMETERS *
      Operating Range Optimum
    Diam. Position Amps Volts WFS
    (in/min)
    ESO Amps Volts WFS
    (in/min)
    .045" Flat 120-320 23-29 140-600 3/8-3/4" 275 28 500
      Vertical Up 120-300 23-27 140-540   250 26 400
      Overhead 125-300 24-28 150-540   250 27 400
    .052" Flat 140-390 24-29 120-550 1/2-1" 340 28 480
      Vertical Up 140-310 24-28 120-450   260 27 300
      Overhead 140-310 24-28 120-450   260 27 300
    1/16" Flat 135-400 22-31 90-460 1/2-1" 340 27 350
      Vertical Up 145-360 23-28 100-350   280 25 250
      Overhead 145-360 23-29 100-350   280 26 250

    * For 90AR-10CO2 shielding gas. Shielding gases with more CO2 may require the voltage to be increased.

    Notice: The results reported are based upon testing of the product under controlled laboratory conditions in accordance with American Welding Society Standards. Actual use of the product may produce different results due to varying conditions. An example of such conditions would be electrode size, plate chemistry, environment, weldment design, fabrication methods, welding procedure and service requirements. Thus the results are not guarantees for use in the field. The manufacturer disclaims any warranty of merchantability or fitness for any particular purpose with respect to its products.

  •