CLASSIFICATIONS: E71T-1C/E71T-1M, E71T-9C/E71T-9M per AWS A5.20,
ASME SFA 5.20
Select 714 is designed for applications where all position capability
is required but horizontal fillet and flat position welding is dominant.
Select 714 performs optimally with 100 percent carbon dioxide shielding,
but can be used with 75-80 percent argon/balance carbon dioxide,
with no deterioration in welding performance.
APPLICATIONS: The good toughness properties of Select 714
make it an especially smart choice for the welding of fine grained
steels, such as ASTM A515 and 516. Typical applications are structural
welds, general steel fabrication, construction equipment and general
railcar welding.
DIAMETERS: .035", .045", .052", 1/16"
SHIELDING GAS: 100% CO2, 75-80% Ar/balance CO2, 35-50 cfh
WELDING POSITIONS: All positions
CHARACTERISTICS:
Much lower fume emissions than conventional rutile-based electrodes.
Specially formulated to produce low spatter horizontal fillets.
Smooth weld bead profile and excellent tie-in.
Very good CVN toughness values at subzero temperatures.
|
TYPICAL
MECHANICAL PROPERTIES
|
| |
CO2
|
75% Ar/ 25% CO2
|
| Ultimate Tensile Strength
(psi) |
80,000 |
90,000 |
| Yield Strength (psi) |
73,000 |
79,000 |
| Percent Elongation |
25 |
22 |
| CVN (ft-lb f)
@ 0° F |
90 |
48 |
| @
-20° F |
68 |
38 |
|
|
TYPICAL
DEPOSIT COMPOSITION
|
| Wt% |
C |
Mn |
P |
S | Si |
|
CO2
|
.02 |
1.28 |
.008 |
.010 |
.52 |
|
75Ar/25 CO2
|
.02 |
1.52 |
.009 |
.010 |
.69 |
|
RECOMMENDED WELDING PARAMETERS |
|
| Diam. |
Position |
Amps |
Volts |
WFS |
Amps |
Volts |
| 1/16" |
Flat |
350 |
29 |
300 |
150-400 |
22-34 |
| |
Overhead |
225 |
26 |
160 |
150-310 |
22-28 |
| |
Vertical up |
225 |
25 |
160 |
150-280 |
22-27 |
| .052" |
Flat |
300 |
28 |
360 |
100-330 |
19-32 |
| |
Overhead |
225 |
26 |
245 |
150-310 |
21-28 |
| |
Vertical up |
225 |
25 |
245 |
150-280 |
21-27 |
| .045" |
Flat |
250 |
28 |
282 |
100-300 |
21-32 |
| |
Overhead |
200 |
26 |
265 |
150-280 |
21-29 |
| |
Vertical up |
200 |
25 |
265 |
100-230 |
21-28 |
| .035" |
Flat |
200 |
27 |
600 |
125-250 |
21-30 |
| |
Overhead |
175 |
25 |
490 |
115-220 |
21-28 |
| |
Vertical up |
170 |
25 |
490 |
120-215 |
21-28 |
|
* With CO2 shielding gas. For 75Ar/25CO2 decrease voltage by 1 to 1.5 volts.
Notice: The results reported are based upon testing of the product under controlled laboratory conditions in accordance with American Welding Society Standards. Actual use of the product may produce different results due to varying conditions. An example of such conditions would be electrode size, plate chemistry, environment, weldment design, fabrication methods, welding procedure and service requirements. Thus the results are not guarantees for use in the field. The manufacturer disclaims any warranty of merchantability or fitness for any particular purpose with respect to its products.
|