CLASSIFICATIONS: E101T1-K3C, K3M per AWS A5.29, ASME SFA 5.29
Select 101-K3C and Select 101-K3M are superb choices for those applications
requiring 100 Ksi minimum tensile strength and good CVN toughness.
These electrodes are intended for single and
multiple pass, all position welding of low alloy steels.
APPLICATIONS: Select 101-K3C and Select 101-K3M are intended
for those weldments
requiring 100 Ksi tensile strength and good subzero toughness. They
are ideal for all position welding of steels such as HY-80, HY-100
and ASTM 514. These materials can be found in shipbuilding, offshore
structures and crane fabrication.
DIAMETERS: .045", .052", 1/16"
SHIELDING GAS: Select 101-K3C (100% CO2), Select 101-K3M (75-80% Ar/balance CO2), 35-50 cfh
WELDING POSITIONS: All positions
CHARACTERISTICS:
Excellent welder appeal in all positions.
Ideal for all position welding of certain HSLA steels.
Weld metal composition is similar to E10018-M.
|
TYPICAL
MECHANICAL PROPERTIES |
| |
|
| Ultimate Tensile Strength
(psi) |
109,200 |
| Yield Strength (psi) |
94,000 |
| Percent Elongation |
21 |
| CVN (ft-lb f)
@ 0° F |
51 |
| @
-20° F |
48 |
|
|
TYPICAL DEPOSIT COMPOSITION |
| Wt% |
C |
Mn |
P |
S |
Si |
Ni |
Mo |
|
|
.04 |
1.50 |
.010 |
.010 |
.30 |
1.75 |
.35 |
|
TYPICAL
WELDING PARAMETERS* |
|
| Diam. |
Position |
Amps |
Volts |
WFS |
Amps |
Volts |
| 1/16" |
Flat |
350 |
29 |
300 |
150-400 |
22-34 |
| |
Overhead |
225 |
26 |
160 |
150-310 |
22-28 |
| |
Vertical
up |
225 |
25 |
160 |
150-280 |
22-27 |
| .052" |
Flat |
300 |
28 |
360 |
100-330 |
19-32 |
| |
Overhead |
225 |
26 |
245 |
150-310 |
21-28 |
| |
Vertical
up |
225 |
25 |
245 |
150-280 |
21-27 |
| .045" |
Flat |
250 |
28 |
282 |
100-300 |
21-32 |
| |
Overhead |
200 |
26 |
265 |
150-280 |
21-29 |
| |
Vertical
up |
200 |
25 |
265 |
100-230 |
21-28 |
|
* With CO2 shielding
gas. For 75Ar/25CO2 decrease voltage by 1 to 1.5 volts.
Notice: The results reported are based upon testing of the product under controlled laboratory conditions in accordance with American Welding Society Standards. Actual use of the product may produce different results due to varying conditions. An example of such conditions would be electrode size, plate chemistry, environment, weldment design, fabrication methods, welding procedure and service requirements. Thus the results are not guarantees for use in the field. The manufacturer disclaims any warranty of merchantability or fitness for any particular purpose with respect to its products.
|